Product

1-channel isolated barrier, 24 V DC supply (Power Rail), Resistance and RTD input (Pt100, Pt500, Pt1000), Resistance output, Accuracy 0.1 %, Line fault detection (LFD) for Pt100, Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508, Rated voltage: 19 ... 30 V DC, Explosion protection: Ex-Input, Field circuit: Resistance, Safe area: Resistance, Transfer direction: to the control system

1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, transmitter power supply, Accuracy 0.1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Output, Field circuit: 4-20 mA, Safe area: 4-20 mA, Transfer direction: to the field, SIL/IEC 61508

1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 0 mA ... 40 mA, I/P or transmitter power supply, Accuracy 1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Output, Field circuit: 0-40 mA, Safe area: 0-40 mA, Transfer direction: to the field, SIL/IEC 61508

2-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, transmitter power supply, Accuracy 0.1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Output, Field circuit: 4-20 mA, Safe area: 4-20 mA, Transfer direction: to the field, SIL/IEC 61508

2-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 0 mA ... 40 mA, I/P or transmitter power supply, Accuracy 1 %, Reverse polarity protection, Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Output, Field circuit: 0-40 mA, Safe area: 0-40 mA, Transfer direction: to the field, SIL/IEC 61508

2-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, Accuracy 0.1 %, Entity parameter Io/Isc = 0 mA, Rated voltage: loop powered, Explosion protection: Ex protection, Field circuit: 4-20 mA, Safe area: 4-20 mA, Transfer direction: to the control system

1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, HART I/P or transmitter power supply, Low voltage drop, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Rated voltage: loop powered, Explosion protection: Ex-Output, Field circuit: 4-20 mA, Safe area: 4-20 mA, Transfer direction: to the field, SIL/IEC 61508

1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 V ... 12 V, Voltage output 0 V ... 12 V, Rated voltage: 20 ... 35 V DC, Explosion protection: Ex-Input, Field circuit: 0-12 V, Safe area: 0-12 V, Transfer direction: to the control system

1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input -10 V ... 10 V, Voltage output -10 V ... 10 V, Rated voltage: 20 ... 35 V DC, Explosion protection: Ex-Input, Field circuit: 0-10 V, Safe area: 0-10 V, Transfer direction: to the control system

1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 mV ... ± 500 mV, Voltage output 0 mV ... ± 500 mV, Selectable up/downscale sensor breakage detection, Rated voltage: 19 ... 30 V DC, Explosion protection: Ex-Input, Field circuit: 0-500 mV, Safe area: 0-500 mV, Transfer direction: to the control system