Tab-Ex 04 Pro DZ2 (DIV 2 and Zone 2/22), latest available Android firmware release, WWAN (optional), with camera (optional), with microSD card (optional)pa
Fieldbus Surge Protector, Field Installation on Trunk
Pluggable, mounts between device coupler and trunk cable, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Optional diagnostics for wear, Grounding of shield via gas-discharge tube, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Europe, USA, Canada, Device coupler location: non-explosion hazardous area Zone 2 - high-power trunk Zone 1 - high-power trunk Division 2 - high-power trunk Division 1 - high-power trunkpa
Thin Client Unit, Modular, lightweight design, Low-power design with minimal heat dissipation, VisuNet RM Shell installed, High connectivity flexibility due to multiple interface options, Certified for ATEX and IECEx Zone 1/21, UL listed for USA and Canada, IP66pa
Niet beschikbaar voor verkoop: For 8 modules, 24 V DC supply, Supported signal types: DI/DO/AI/TI/AO, Hazardous area: screw terminals, blue, Non-hazardous area: screw terminals, black, Number of modules: 8, Number of channels per module: 2 , 4, Signal type: Universal, Manufacturer: Universal, Control system type: Universalpa
Niet beschikbaar voor verkoop: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Niet beschikbaar voor verkoop: 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: 2-wire connection, Type [2]: 3-wire connection, Type [3]: 4-wire connection, Field device: resistance thermometerpa
Niet beschikbaar voor verkoop: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Niet beschikbaar voor verkoop: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Niet beschikbaar voor verkoop: 1-channel signal conditioner, Universal usage at different power supplies, Input 2-wire and 3-wire transmitters, current and voltage sources, Current and voltage output, Housing width: 20 mm, Number of channels: 1-channel, Rated voltage: 19 ... 90 V DC / 48 ... 253 V AC, Field device: 2-wire transmitter, Field device [2]: 3-wire transmitter, Field device [3]: current source, Signal: 0/4 ... 20 mA, Signal [2]: 0/2 ... 10 V, Signal: 1 x 0/4 ... 20 mA (current source), Signal [2]: 1 x 0/2 ... 10 Vpa
Niet beschikbaar voor verkoop: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Niet beschikbaar voor verkoop: 2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact), Reversible mode of operationpa
Pepperl+Fuchsbiedt u een volledigeIO-Link-systeemoplossing die een ruimassortiment van IO-Link-sensoren en bijbehorendeinfrastructuuromvat ... , bijvoorbeeld in magazijnactiviteiten en materialhandling... Meer info In alle situatieswaarinconventionelesignaallampen hun limietenbereiken, biedt de nieuwesignaallampextrafuncties, dankzij de geïntegreerdeIO-Link-interfaceV1.1 (COM3/KlasseA ...
De op LoRaWANgebaseerdeultrasoneWILSEN-sensor van Pepperl+Fuchs is een robuusteoplossing voor vulniveaubewaking en afstandsmeting ... DownlinkChannelHowdoyouparameterizetheWILSENsensorsfromPepperl+Fuchs via thedownlinkchannel ? In thisvideo, ourexpertshowsyouhowtosetitupquicklyandeasily. LoRaWAN® Op IoTafgestemdetechnologie met talrijkevoordelen Als lid ...
Ontvang een overzicht van de uitgebreideportfolio van HMI-systemen van Pepperl+Fuchs voor procesindustrieën ... ® Celeronandi5embeddedprocessor (KabyLake) van de zevendegeneratie. Ze ondersteunentevens de meest recente, supersnelleopslagtechnologie (M.2NVMe1.3) en uitgebreideRAM-configuraties tot 16GBDDR4-geheugen. Industriëlethinclients en box-pc’s ...
Naast de beproefdefunctiesbeschikken de Tab-Ex® tablets over innovatievefeatures zoals de integratie van augmentedreality-apps die de implementatie van Industrie40/IIoT-toepassingenvereenvoudigen ... : 162,1x256,0x33,3mm, 1250gTab-Ex® 02DZ2: 127,6x214,7x9,9mm, 575g (Wi-Fi) / 579g (LTE) 243,5x170,2x9,9mm; 850g (D2), 930g (DZ2) OperatingtemperatureTab-Ex® 02DZ1: -20 °C ... +50 °CTab-Ex® 02DZ2: -20 °C ... +55 °C -20 °C ... +55 °C ...
Pepperl+Fuchs' VisuNetFLX-productlijnbiedt u de vrijheid en flexibiliteit om een op maatgemaakteHMI-oplossing te creëren die exact aan uw behoeftenvoldoet, of het nu een volledigHMI-systeem, panel-pc, thinclient of directmonitor is ... (32 … 104 °F) VisuNetFLXExtendedTemperatureRangeRM-320S-*B-* (RemoteMonitor) PC-320S-*B-* (IndustrialPC) DM-320S-*B-* (DirectMonitor) 21,5” (16:9, FullHD: 1920x1080px), 300cd/m², opticallybondedNon-ExATEX/IECExZone2/22ULClassI, II ...
1-5/926Artikelen per pagina:
No results found?
Hint: Use wildcard character * before your search term, modify your search, check your search terms for misspellings, or contact us with your specific request.