7500 series vent EPV-7500-AA-02

EPV-7500-AA-02
  • Must be used in conjunction with a 7500-01-AA* or 7500-MTD-* purge and pressurization control unit
  • Low cost, universal mounting, easy to use
  • Not gravity dependent
  • Various enclosure protection vents for different applications
  • Rugged, corrosion-resistant housing
  • Mechanical with no cables
  • Global third-party approvals for Class I, II, Div. 2 and Zone 2/22

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Technische gegevens  EPV-7500-AA-02

Productbeschrijving
7500 series purge and pressurization system vent, aluminum body and cap
General specifications
Equipment architecturemax. enclosure size 12.7 m3 (450 ft3)
Series7500
SystemType Z Purge ; Ex pzc Purge
Hazardous environmentgas or dust
Pneumatic parameters
Protective gas supplycompressed air or inert gas, 40 µm filter, free from oil
Maximum pressureSee tables
Purge flow rateSee tables
Flow rate for leakage compensationEPV-7500....-01:
approx. 25 scfh (707 l/hr) at 0.25 in wc (0.63 mbar)
approx. 65 scfh (1838 l/hr) at 0.75 in wc (1.9 mbar)
EPV-7500....-02:
approx. 20 scfh (565 l/hr) at 0.25 in wc (0.63 mbar)
approx. 48 scfh (1357 l/hr) at 0.75 in wc (1.9 mbar)
EPV-7500....-03 and EPV-7500-AA-04:
approx. 15 scfh (424 l/hr) at 0.25 in wc (0.63 mbar)
approx. 25 scfh (707 l/hr) at 0.75 in wc (1.9 mbar)
Breaking pressureEPV-7500....-01: 0.8 in wc (2.0 mbar)
EPV-7500-...-02: 1.4 in wc (3.5 mbar)
EPV-7500-...-03: 1.5 in wc (3.8 mbar)
EPV-7500-AA-04: 1.4 in wc (3.5 mbar)
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 , FCC CFR 47, part 15, subpart B: 2017, Class A ICES-003, Issue 6:2016, Class A ITE
RoHS
Directive 2011/65/EU (RoHS)EN 50581:2012
Conformity
Degree of protectionDirective conformity: see Declaration of Conformity
Ambient conditions
Ambient temperature-40 ... 70 °C (-40 ... 158 °F)
Storage temperature-40 ... 80 °C (-40 ... 176 °F)
Relative humidity5 ... 90 %, non-condensing
Vibration resistance5 ... 100 Hz , 1 g, 12 m/s2, all axes
Impact resistance30 g, 11 ms, all axes
Mechanical specifications
Degree of protectionEPV-7500....-01/02/04: mounting only Type 4X / IP66
EPV-7500....-03: Mounting and unit Type 4X / IP66
Material
HousingEPV-7500-AA... body and cap: 6061-T6 aluminum
EPV-7500-SS... body: 6061-T6 aluminum
cap: AISI 316L (1.4404) stainless steel
Spark arrestor304 Stainless steel
Installation- any orientation to enclosure
- not gravity dependent
- internal and external mounting possible
Massapprox. 1000 g (2.2 lb)
DimensionsSee "Dimensions" section.
MountingEPV-7500-...-01/02/03: mounting hole 1.5 in NPT knockout (50.8 mm) hole sealing nut (provided)
EPV-7500-AA-04: mounting hole 37 mm with sealing nut (provided)
Data for application in connection with hazardous areas
Certificate
MarkingEx-Hexagon II 3GD (part of DEMKO 18 ATEX 2025 X)
Directive conformity
Directive 2014/34/EUIEC/EN 60079-0 , IEC/EN 60079-2 , IEC/EN 60079-7 , IEC/EN 60079-15 , IEC/EN 60079-18 , IEC/EN 60079-31
Supplements: EN 61010-1:2010, EN 61326-3:2008, EN 61000-6-2:2005
International approvals
UL approval
cULusClass I, Division 2, Groups A, B, C, D T4 (-40 °C ≤ Ta ≤ 70 °C)
Class I, Division 2, Groups A, B, C, D, T6 (-40 °C ≤ Ta ≤ 50 °C)
Class II, Division 2, Groups F, G T4 (-40 °C ≤ Ta ≤ 70 °C)
Class II, Division 2, Groups F, G T6 (-40 °C ≤ Ta ≤ 50 °C)
IECEx approvalpart of IECEx UL 18.0022X

Classifications

SystemClasscode
ECLASS 13.027180591
ECLASS 12.027180591
ECLASS 11.027180591
ECLASS 10.0.127292190
ECLASS 9.027292190
ECLASS 8.027292190
ECLASS 5.140050501
ETIM 9.0EC000243
ETIM 8.0EC000243
ETIM 7.0EC000243
ETIM 6.0EC000243
ETIM 5.0EC000243
UNSPSC 12.139121303

Details: EPV-7500-AA-02

Datasheet: EPV-7500-AA-02

DatasheetBestandstypeBestandsgrootte
Datasheet EPV-7500-AA-02PDF642 KB
Datenblatt EPV-7500-AA-02PDF811 KB

CAD+CAE: EPV-7500-AA-02

CADBestandstypeBestandsgrootte
CAD 2-D / CAD 2-DZIP406 KB
CAD 3-D / CAD 3-DSTP3302 KB
CAD Portal / CAD PortalLINK---

Approvals+Certificates: EPV-7500-AA-02

CertificatesBestandstypeBestandsgrootte
ATEX CertificatePDF551 KB
Brasil TUV Rheinland BrazilPDF1303 KB
IECEx Certificate of ConformityLINK---
Korea KOSHAPDF504 KB
UL Hazardous LocationPDF349 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)PDF171 KB
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F)PDF167 KB

Aanverwante producten: EPV-7500-AA-02

Accessory of
You must purchase an EPV-7500-* vent with this control unit.pa
You must purchase an EPV-7500-* vent with this control unit.pa
You must purchase an EPV-7500-* vent with this control unit.pa
You must purchase an EPV-7500-* vent with this control unit.pa

Ontdek de slimste manier om uw explosiegevaarlijke omgeving te beschermen en stel uw eigen purge- en overdruksysteem samen!

Dit purge- en overdruksysteem brengt explosiebeveiliging tot nieuwe hoogtes qua innovatie en betrouwbaarheid. Ontworpen voor Class I of II/Div. 2 en Zone 2/22 omgevingen, biedt het unieke features in een ultracompacte behuizing…